Heizplatte wird nicht warm

Geändert am Do, 27 Feb um 10:37 VORMITTAGS



Secabo Support Notes

Secabo TPD7 Press




Error: The Heatplate does not heat up




  1. Unplug the press from mains



  1. Unscrew the protection case of the press at the 2x screws on each side


















  1. Open the protection case and secure it to prevent the case from falling down. Additionally, you can disconnect the fan. 



  1. Unscrew the cable attached to connection 1 and connect both, cable 1+ 2 to connector 2





  1. Close the baffle and plug in the mains cable

  2. Switch “ON” the press 



WARNING: The Heatplate will immediately heat up if functioning. Please make sure to stop the test as soon as the Heatplate gets noticeably warm. As soon as the Heatplate warms up, switch “OFF” the press to prevent it from overheating. 





The test helps us to find out which parts are defective. There are two possible outcomes:: 


1. the plate heats up                  --> the Solid State Relay is defective

2. the plate does not heat up     --> the Heatplate is defective